Build an Energy List for the Application
For a generic RV day, assume a DC refrigerator averages 60 W over twelve hours, lighting uses 20 W for five hours, and a router uses 10 W for eight hours. Also include an AC appliance drawing 500 W for two hours through an inverter.
| Load | Example use | Battery energy required |
|---|---|---|
| DC refrigerator | 60 W average × 12 hours | 0.72 kWh DC |
| DC lighting | 20 W × 5 hours | 0.10 kWh DC |
| DC router | 10 W × 8 hours | 0.08 kWh DC |
| AC appliance through inverter | 500 W × 2 hours ÷ 90% efficiency | About 1.11 kWh DC |
| Total | For the stated daily use | About 2.01 kWh DC |
The DC load figures are assumed at the battery side; the inverter loss applies only to the AC appliance. The example excludes additional standby and wiring losses. Refrigeration demand should be measured over a representative period because compressor cycling and ambient temperature affect consumption.
If 90% of the nominal 3.84 kWh were usable, the available energy would be 3.84 × 0.90 = 3.456 kWh DC. That exceeds the example’s 2.01 kWh day, before allowing for reserve, changing conditions, and aging. The 90% usable fraction is an assumption, not a rating for a MINGWATT model. See the capacity guide for the distinction between nominal and usable energy.
To translate a load plan into operating hours, calculate 12V 300Ah battery runtime using the AC, DC, and simultaneous-load examples.
Match the Current Rating to the Largest Load
For an inverter supplying 1,500 W AC at 90% efficiency while the battery operates at 12.0 V under load, the estimated battery current is:
1,500 ÷ (12.0 × 0.90) ≈ 139 A DC
A hypothetical battery limited to 100 A continuous output would not support that steady load, even with plenty of stored energy. Other DC loads would add to the current. Check the complete battery’s rating, including its BMS, connections, and permitted temperature range, along with the inverter’s startup requirements.
Manufacturer data sheets illustrate why these are separate checks. Victron’s Lithium Smart technical data lists capacity, charge current, discharge current, and operating temperatures independently. Use the limits for the product being quoted.
Review Every Charging Source
An RV or off-grid installation may charge from shore power, a solar controller, and a vehicle alternator. Ask the installer to check the voltage profile, current limit, temperature controls, and BMS coordination for each source.
A charger previously used for lead-acid needs its actual settings checked against the selected LiFePO4 battery’s instructions. Modes such as equalization or reconditioning require particular attention; a “12V” label alone does not establish compatibility. A manufacturer’s charging and operating instructions show the level of detail needed, including different limits for charging and discharging.
For alternator charging, have the installer assess current control and how charging stops when the battery requests it. Victron’s system design guide discusses alternator loading and current-limiting options. The appropriate arrangement depends on the vehicle and battery system.
Confirm the Battery Fits the Job and the Compartment
Measure the available space, including terminals, cables, restraints, and access. Obtain the battery’s mass, permitted mounting position, enclosure rating, and installation instructions. For a cold-weather application, confirm the charging temperature limit and whether any claimed heater is fitted and how it operates.
If several batteries are planned, request the manufacturer’s permitted series or parallel configurations and the requirements for the complete bank. Also identify the intended duty. Engine starting and vehicle traction need application-specific approval and ratings. For propulsion, use the electric three-wheeler battery selection guide.
When comparing offers, request the exact model data sheet, usable-energy basis, continuous and peak-current ratings, charger requirements, warranty, and supported expansion arrangements.
For a MINGWATT lead-acid replacement enquiry, send your application, existing battery and charger labels, largest load, daily energy estimate, and compartment dimensions. Ask for the available model that meets those conditions; the calculations above are generic and do not identify a particular product.