LEAD-ACID REPLACEMENT GUIDES

12V 300Ah LiFePO4 Battery Runtime: Calculation and Examples

A 12.8 V, 300Ah LiFePO4 battery can supply a steady 500 W AC load for about 6.2 hours, or a 1,000 W load for about 3.1 hours, assuming 90% usable energy and 90% inverter efficiency. These calculations start with the full usable energy available, without recharging or additional standby consumption. They are not performance ratings for a MINGWATT model.

For a refrigerator, lighting, or an inverter supplying several appliances, the calculation changes with the average load and where that load is measured. Keep the DC battery side and AC appliance side separate.

Convert 300Ah Into Stored Energy

A battery sold in the 12V class may specify 12.8 V nominal. Use the actual data-sheet value:

12.8 V × 300 Ah = 3,840 Wh, or 3.84 kWh nominal

With an assumed 90% usable fraction, available battery energy is 3.84 × 0.90 = 3.456 kWh DC. Passing this through an inverter at an assumed 90% efficiency gives 3.456 × 0.90 = 3.1104 kWh AC.

The usable fraction is an example, not a recommended discharge setting. If your supplier already specifies usable energy, start with that figure. See the capacity and usable-energy guide to avoid deducting the same allowance twice.

Runtime at Five AC Loads

Divide available AC energy by average AC load. Convert watts to kilowatts before dividing kWh by kW.

Calculated runtime from 3.1104 kWh AC, with full starting usable energy and no recharge or additional standby draw
Steady AC loadCalculationApproximate runtime
100 W3.1104 ÷ 0.131.1 hours
300 W3.1104 ÷ 0.310.4 hours
500 W3.1104 ÷ 0.56.2 hours
1,000 W3.1104 ÷ 1.03.1 hours
1,500 W3.1104 ÷ 1.52.1 hours

Every row is conditional on the battery and inverter supporting the load. The fixed 90% efficiency makes the examples comparable; actual efficiency changes with load. At low power, additional inverter consumption can noticeably shorten runtime.

For cycling appliances, use measured energy over a representative period. A refrigerator's compressor rating is not its average demand over a day. Divide recorded Wh by measurement hours to obtain average watts.

DC Loads and Mixed AC/DC Loads

A DC load measured at the battery terminals does not need an inverter-loss allowance. A steady 100 W draw at that measurement point would give 3.456 ÷ 0.1 = 34.56 hours under the same usable-energy assumption. If you measure at the appliance instead, include losses in any intervening converter and wiring.

Now suppose an inverter supplies 500 W AC while separate DC equipment draws 60 W at the battery side. With 90% inverter efficiency, total battery demand is:

500 ÷ 0.90 + 60 = 615.6 W DC
3,456 Wh ÷ 615.6 W ≈ 5.6 hours

This assumes both loads remain constant and excludes additional standby consumption. The AC-only 500 W estimate of 6.2 hours would overstate runtime because it misses the separate DC load.

Check Current Before Relying on the High-Load Rows

For the 1,500 W AC example, a battery operating at 12.0 V under load would supply approximately 1,500 ÷ (12.0 × 0.90) = 139 A DC. A hypothetical battery limited to 100 A continuously could not sustain that demand, regardless of the energy remaining.

Check the complete battery's continuous current, permitted peak duration, and temperature limits, as well as inverter startup requirements. Victron's Lithium Smart technical data lists capacity, temperature-dependent ratings, and current limits separately. Obtain equivalent information for your chosen model rather than applying those product-specific ratings to another battery.

Turn the Estimate Into a Practical Load Plan

Record the loads, their operating hours, and whether their consumption is measured on the AC or DC side. Check how much usable energy will remain when you start. Half the available usable energy gives half the calculated runtime at an unchanged load; an app's displayed percentage needs to be interpreted using that system's documentation.

Allow for temperature, aging, and auxiliary consumption that the chosen energy or efficiency figure does not already include. If solar or another source will recharge the battery, calculate that contribution separately and use a conservative estimate for the period concerned.

Use the 300Ah application guide for charger and installation checks, or compare 280Ah and 300Ah batteries if you are deciding between capacities.