Start with the Energy You Need to Add
A partly charged battery needs enough energy to reach your chosen target. For this example, assume the amount still to be stored is 6 kWh. That could be the energy used during the previous discharge period, adjusted for the level you want to restore. If you are planning around an overnight load, the home battery runtime guide shows how energy use changes with load and duration.
If you estimate this amount from state of charge, check what the percentage in your monitoring app represents. Multiplying a percentage change by nominal capacity gives only an approximation of stored energy. Usable capacity, the manufacturer’s state-of-charge calculation, and system settings affect the result.
Then decide where charging power is being measured. The worked example below measures power at the charger’s AC input and includes losses through to stored energy. If your system provides an estimate of the rate at which stored energy is increasing, use that rate directly.
What 1 kW, 2 kW, and 3 kW of Charging Power Deliver
Charging time (hours) ≈ energy to store (kWh) ÷ [average AC charging input (kW) × charging efficiency]
| Average AC input to charging | Average rate of stored energy increase | Calculated time |
|---|---|---|
| 1 kW | 0.9 kW | About 6 hours 40 minutes |
| 2 kW | 1.8 kW | About 3 hours 20 minutes |
| 3 kW | 2.7 kW | About 2 hours 13 minutes |
The example uses constant average power. Reaching a full-charge indication can take longer if the charge profile reduces current near the target or allows time for cell balancing. Follow the profile specified for the exact battery. Manufacturer documentation illustrates how charging stages and balancing time form part of the process. See an example charging profile.
A three-hour charging window at 2 kW would add 2 × 0.90 × 3 = 5.4 kWh under these assumptions. To add 6 kWh in that window, the required average AC charging input would be about 6 ÷ (3 × 0.90) = 2.22 kW. The battery and charger must both support that rate throughout the intended operating range.
Solar Charging Depends on the Power Left After Household Use
Consider an AC-coupled example in which the solar inverter is producing 3 kW and the house is using 1 kW on the same AC side of the system. That leaves 2 kW available to the battery charger, assuming its settings permit charging and its limits allow that power.
If the 2 kW surplus continued, the six-kWh example would again take about 3 hours 20 minutes. In practice, cloud cover and changing household demand alter the surplus. A midday reading is useful for understanding the power flow, while an estimate for the whole charging period needs the surplus over that period.
During a power cut, solar charging also depends on the system’s backup design. Confirm whether the solar inverter can operate and recharge the battery while disconnected from the grid. The guide to home batteries during a power outage covers that check.
Find the Limit That Controls Your System
Review the inverter or charger’s battery charging rating, the battery’s permitted charge current, and any limits sent by the BMS. Also check the configured charging schedule and whether household loads reduce the power available from the source. For the equipment checks, see How to Check Battery–Inverter Compatibility.
Planning a battery system? Share your inverter or charger brand and exact model, battery voltage, charging source, energy to restore and time available. We can review the stated limits and identify the compatibility information still needed.