HOME BATTERY GUIDES

How to Size a Home Backup Battery

To size a home backup battery, add up the electricity your essential appliances will use during an outage, account for conversion losses, and allow extra capacity for uncertainty. Then check whether the battery and inverter can supply the loads that will run together.

For example, if your essential loads use 1.26 kWh of AC electricity over six hours, a system with 90% assumed conversion efficiency and 20% extra capacity for planning would need about 1.68 kWh of usable battery energy under those assumptions. The system also needs enough power to start and run the connected appliances.

1. List the Loads You Want to Back Up

Start with the appliances and circuits you want to keep running during an outage. For essential-load backup, that might include a refrigerator, internet equipment, and selected lights. For whole-home backup, include all circuits that may operate during the outage, especially larger loads such as air conditioning, electric water heating, and pumps.

Record the power draw in watts and the expected running time for each load. For a device that cycles on and off, such as a refrigerator, use its measured energy consumption over a representative period when available. A refrigerator can stay connected for six hours while its compressor runs for only part of that time.

2. Calculate the Electricity Your Loads Will Use

For a load with a reasonably steady power draw, use this formula.

Load energy (kWh) = power (W) × running time (hours) ÷ 1,000

Add the energy for all loads to get the total AC electricity needed during the outage. Use the same backup window for the whole calculation, with a running time appropriate to each device.

Generic load example for a six-hour outage
Example loadAssumed running powerRunning time in a six-hour outageAC energy
Refrigerator120 W3 hours of compressor operation0.36 kWh
Modem and router20 W6 hours0.12 kWh
LED lighting40 W total6 hours0.24 kWh
Laptop and monitor90 W total6 hours0.54 kWh
Total1.26 kWh

These figures illustrate the calculation. Use your own measurements or equipment data when sizing a system. This example assumes the battery supplies the loads throughout the outage, with no solar generation or generator contribution.

3. Convert AC Energy into Usable Battery Capacity

The battery has to supply the loads and cover losses between the battery and the AC output. For this example, assume 90% conversion efficiency and use a 20% planning margin.

Usable battery energy needed (kWh) = AC load energy (kWh) ÷ conversion efficiency × (1 + planning margin)

Worked Example

  • Battery energy required before the margin is 1.26 ÷ 0.90 = 1.40 kWh.
  • With 20% extra capacity, the target is 1.40 × 1.20 = 1.68 kWh of usable battery energy.

The efficiency and margin are assumptions for this example. Use system-specific efficiency data where available. If inverter standby consumption is excluded from the efficiency estimate, account for it separately. Also check how much energy will be available at the start of an outage, given the battery’s expected state of charge and the system’s minimum discharge setting. A partly charged battery may require a larger installed capacity to provide the same available energy.

When comparing battery specifications, check whether the listed kWh refers to nominal energy, usable battery energy, or energy delivered at the AC output. For the calculation above, compare the result with usable battery energy under the intended operating conditions. For a worked comparison of all three figures, see Battery Capacity Explained: kW, kWh, and Usable Energy.

4. Check Continuous and Startup Power

Capacity in kWh helps determine how long the system can run. Power in kW determines which loads it can support at the same time.

In the example, the four loads draw 270 W if they are all running at their listed power. That figure excludes the refrigerator’s startup demand. Check the following before selecting a system.

  • The inverter’s continuous backup output must cover loads expected to run together.
  • Its surge output and supported surge duration must cover startup demand from equipment such as compressors and pumps.
  • The battery’s continuous and peak discharge limits, together with the inverter’s battery-side limits, must support those operating demands.

If you already have an inverter, record its exact model and firmware version. Use How to Check Battery–Inverter Compatibility to check the supported battery pairing, voltage range, current limits, and communication requirements.

What to Share When Requesting a Battery Recommendation

Send your installer or MINGWATT the following details.

  • The appliances or circuits you want to back up, including any large motors or compressors
  • Measured energy use or appliance power ratings and estimated running times
  • Your target backup duration
  • Your existing inverter model and firmware version, if applicable
  • Your installation country and whether you need essential-load or whole-home backup

Share your load list and backup requirements so we can review the product information needed for your project.